import os
import pprint
import time
from datetime import datetime
from energy_monitor import CONN_STR, DatabaseManager, PlcManager
from logger_setup import setup_logger
# Globals
DEVICE_DELAY = 1 # Delay between device data fetches
POOL_RATE = 2 # 2s polling rate reading of NextRead value from database
FALLBACK_INTERVAL = 20 # 1h = 3600s interval in case db read issue
# Logger setup
logger = setup_logger()
def process_plc_devices(db_manager: DatabaseManager, plc_manager: PlcManager):
plc_configs = db_manager.get_plc_configs()
# If debug print out plc_configs to logs
logger.debug(
{
"msg": "Retrieved PLC configurations",
"plc_configs": [
{
"id": plc.id,
"ip": plc.ip,
"location": plc.location,
"is_enabled": plc.is_enabled,
"db_number": plc.db_number,
}
for plc in plc_configs
],
"timestamp": datetime.now().isoformat(),
},
)
for plc_config in plc_configs:
try:
if not plc_manager.check_connection(plc_config.ip):
logger.error(
{
"msg": "PLC connection failed",
"PlcId": plc_config.id,
"PlcIp": plc_config.ip,
"timestamp": datetime.now().isoformat(),
}
)
continue
air_value, energy_value, run_status = plc_manager.read_plc_data(plc_config)
db_manager.save_energy_data(plc_config.id, energy_value, air_value, True)
logger.info(
{
"msg": "✅ Data successfully read and saved",
"PlcId": plc_config.id,
"PlcIp": plc_config.ip,
"energy_value": energy_value,
"air_value": air_value,
"timestamp": datetime.now().isoformat(),
},
)
time.sleep(DEVICE_DELAY) # n-second delay between devices
except Exception as e:
logger.error(
{
"msg": "Error reading PLC data",
"PlcId": plc_config.id,
"PlcIp": plc_config.ip,
"error": str(e),
"timestamp": datetime.now().isoformat(),
},
)
def main():
db_manager = DatabaseManager(CONN_STR)
plc_manager = PlcManager()
pprint.pp(
{
"SQL_Config": {
"Server": os.getenv("DB_SERVER"),
"Database": os.getenv("DB_NAME"),
"User": os.getenv("DB_USER"),
# Masking password for security
"Password": "****",
},
"SEQ_Config": {
"URL": os.getenv("SEQ_URL"),
# Masking API key for security
"API_Key": "****",
},
"timestamp": datetime.now().isoformat(),
}
)
while True:
try:
scheduler_config = db_manager.get_scheduler_config()
if datetime.now() >= scheduler_config.next_read:
process_plc_devices(db_manager, plc_manager)
db_manager.update_next_read(scheduler_config.interval)
time.sleep(POOL_RATE)
except Exception as e:
logger.error(
{
"msg": "Main loop error! Falling back to 1h interval.",
"error": str(e),
"timestamp": datetime.now().isoformat(),
},
)
time.sleep(FALLBACK_INTERVAL) # Default fallback interval
if __name__ == "__main__":